Functions and Operations
Section 5 Functions and Operations
5-48
D Use the U[UP] and S[SHIFT] Keys to
set the password "-0169". Press the
M[MODE] Key to move to the
advanced-function setting level.
•"
L
f" is displayed on the level/bank
display to indicate the advanced-
function setting level.
E Press the M[MODE] Key several times
to change the PV display to "o-stp".
F Press the S[SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
G Use the U[UP] Key to change the set
value.
H Press the M[MODE] Key to switch to
the next parameter.
• The set value is registered.
I Press the L[LEVEL] Key for at least 1
s to return to the initial setting level.
1 s min.
J Press the L[LEVEL] Key for at least 1
s to return to RUN level.
1 s min.
SU
M
init
Displays "
L
f".
off
L
f
M
o-stp
L
f
off
S
o-stp
L
f
off
U
o-stp
L
f
on
M
t-zr
off
L
f
L
cal
0
L
0
L
123. 4
123. 4