EasyManuals Logo

Omron M1 Series User Manual

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
Power supply
system
Standard applicable
motor (kW)
Inverter Model
HHD/HD/HND/ND
modes
Tightening torque
lb-in (Nm)
Wire size AWG (mm
2
)
Main Terminal
Inverter's
grounding
Control circuit
auxiliary input
Main circuit copper wire
G
Control circuit
auxiliary input
L1/R, L2/S, L3/T U, V, W
60°C Cu Wire
75°C Cu Wire
Remarks
60°C Cu Wire
75°C Cu Wire
Remarks
Inverter's
grounding
Thre
e-
phas
e
400
V
0.4 3G3M1-
A4004
HHD 10.6
(1.2)
15.9
(1.8)
- 14
(2.1)
14
(2.1)
*3
14
(2.1)
14
(2.1)
*3
14
(2.1)
-
0.75 3G3M1-
A4004
HD/
HND
3G3M1-
A4004
ND
3G3M1-
A4007
HHD
1.1 3G3M1-
A4007
HD/
HND
1.5 3G3M1-
A4007
ND
3G3M1-
A4015
HHD
2.2 3G3M1-
A4015
HD/
HND
12
(3.3)
3G3M1-
A4015
ND
3G3M1-
A4022
HHD
3 3G3M1-
A4022
ND
3G3M1-
A4022
HD/
HND
3G3M1-
A4030
HHD
4 3G3M1-
A4030
ND/
HD/
HND
3G3M1-
A4040
HHD 10
(5.3)
5.5 3G3M1-
A4040
ND 12
(3.3)
12
(3.3)
3G3M1-
A4040
HD/
HND
3G3M1-
A4055
HHD 27
(3)
27
(3)
2 Design
2-79
M1 Series Standard Type User's Manual (I669)
2-4 Others
2
2-4-3 UL/cUL Standards Cautions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C