Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
J64
Overload Stop Detec-
tion Level
20 to 200%
100
Availa-
ble
%
page
7-153
J65
Overload Stop Mode
Selection
0: Disable
1: Deceleration stop
2: Free run stop
3: Mechanical stop
0 - -
page
7-153
J66
Overload Stop Opera-
tion Mode
0: During constant speed run-
ning and deceleration
1: During constant speed run-
ning
2: Anytime
0
Availa-
ble
-
page
7-153
J67
Overload Stop Detec-
tion T
imer
0.00 to 600.00 s
0
Availa-
ble
s
page
7-153
J68
Brake Control Brake-
release Current
0.00 to 300.00 %
100.00
Availa-
ble
%
page
6-76
J69
Brake Control Brake-
release Frequency
0.0 to 25.0 Hz
1.0
Availa-
ble
Hz
page
6-76
J70
Brake Control Brake-
release T
imer
0.000 to 5.000 s
1.000
Availa-
ble
s
page
6-76
J71
Brake Control Brake-
applied Frequency
0.0 to 25.0 Hz
1.0
Availa-
ble
Hz
page
6-76
J72
Brake Control Brake-
applied T
imer
0.000 to 5.000 s
1.000
Availa-
ble
s
page
6-76
J90
Overload Stop Func-
tion P gain
0.000 to 2.000 times
999: 0.050 times
32767
Availa-
ble
-
page
7-153
4 Parameter List
4-146
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C