Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
d08
Speed Control 1 Notch
Filter Attenuation Lev-
el
0 to 40 dB
0
Availa-
ble
dB
page
6-26
d09
Speed Control Jog-
ging Speed Command
Filter
0.000 to 5.000 s
0.02
Availa-
ble
s
page
5-60
d10
Speed Control Jog-
ging Speed Detection
Filter
0.000 to 0.100 s
0.005
Availa-
ble
s
page
5-60
d11
Speed Control Jog-
ging P Proportional
Gain
0.1 to 200.0
10
Availa-
ble
-
page
5-60
d12
Speed Control Jog-
ging I Integral Time
0.001 to 9.999 s
999: Cancel integral term
0.1
Availa-
ble
s
page
5-60
d13
Speed Control Jog-
ging Output Filter
0.000 to 0.100 s
0.002
Availa-
ble
s
page
5-60
d14
Input Terminal [PIA]
[PIB] Pulse Input For-
mat Selection
0: Pulse train signing/pulse
train input
1: Forward/reverse rotation
pulse
2: Quadrature A/B signal (B
phase lead)
3: Quadrature A/B signal (A
phase lead)
2 - -
page
6-11
page
7-145
d15
Input Terminal [PIA]
[PIB] Encoder Pulse
Resolution
20 to 60000
1024 - -
page
6-11
page
7-145
d16
Input Terminal [PIA]
[PIB] Pulse Scaling
Factor Denominator
1 to 32767
1
Availa-
ble
-
page
6-11
page
7-145
d17
Input Terminal [PIA]
[PIB] Pulse Scaling
Factor Numerator
1 to 32767
1
Availa-
ble
-
page
6-11
page
7-145
4 Parameter List
4-149
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-10 Parameter d (Applied Functions 2)