Parameter
No.
MODBUS ad-
dress (MSB)
MODBUS ad-
dress (LSB)
Parameter name
Communica-
tion data for-
mat (during
single-word
access)
Communica-
tion data for-
mat (during
double-word
access)
H95 3424h -
DC Injection Braking Start
Characteristic Selection
1 -
H96 3425h -
STOP Key Priority/Start
Check Function
1 -
H98 3427h -
Protection/Maintenance Func-
tion Mode Selection
1 -
H99 3428h -
Password 2 Setting/Verifica-
tion
1 -
H114 348Eh -
Anti-regenerative Control Lev-
el
3 -
H116 3490h - Reserved 1 -
H117 3491h - Reserved 3 -
H118 3492h - Reserved 3 -
H119 3493h - Reserved 1 -
H120 3494h - Reserved 1 -
H121 3495h - Reserved 3 -
H130 349Eh - Reserved 7 -
H131 349Fh - Reserved 7 -
H133 34A1h - Reserved 7 -
H134 34A2h - Reserved 7 -
H147 34AFh -
Speed Control Jogging Feed
Forward Gain
5 -
H154 34B6h -
Torque Bias Function Selec-
tion
1 -
H155 34B7h - Torque Bias Level 1 2 -
H156 34B8h - Torque Bias Level 2 2 -
H157 34B9h - Torque Bias Level 3 2 -
H158 34BAh -
Torque Bias Mechanical Loss
Compensation
1 -
H159 34BBh - Torque Bias Startup Timer 5 -
H161 34BDh - Torque Bias Shutdown Timer 5 -
H162 34BEh - Torque Bias Limit 1 -
H173 34C9h -
Magnetic Flux Level at Light
Load
1 -
H180 34D0h - Brake Error Detection Time 5 -
H185 34D5h - Reserved 1 -
H193 34DDh -
User Preference Dataset Reg-
istration
1 -
H194 34DEh -
User Preference Dataset Pro-
tection Function Selection
1 -
H195 34DFh -
DC Injection Braking Startup
T
ime
5 -
H196 34E0h -
Reserved 7 -
H197 34E1h -
User password 1 Mode selec-
tion
1 -
8 Communications Functions
8-60
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C