ix
OS32C
User’s Manual
Introduction
E
When transferring data from the PC to the OS32C and more than one OS32C is connected to the
network, it is necessary to visually check the diagnostic code on the status/diagnostic display. It is
recommended that the OS32C be installed in a position where the status/diagnostic display will be
visible.
Take precautions to prevent dirt, dust or debris from entering the sensor and I/O block connectors.
It is recommended that this be done on a clean workstation as contaminants may degrade the
performance of the OS32C.
Adhesion of dust to the scan window may cause a false operation. The OS32C will require periodic
cleaning of the scan window and dust detection surface.
Operation of the OS32C may be affected by light in the environment, such as incandescent light,
strobe light and light from a photosensor using infrared light.
Operation of the OS32C may be affected by substances in the environment, such as fog, smoke,
steam and other small particles.
Ensure the measurement report configuration matches the expected measurement data format.