76
Chapter3
OS32C
User’s Manual
Basic Operation of Configuration Software
Record System Monitoring
Live system monitoring can be recorded to a file. This option is only available after successfully logging on to
the scanner in either operator or supervisor mode. The user can specify where the recording is to be saved as
well as the recording duration.
- Recording will not be interrupted if the PC goes into screensaver mode.
- Minimum recording duration is 5 seconds. Maximum recording duration is determined by the type of storage device. NTFS
type storage devices will have a 96 hour limit. FAT32 type storage devices will have a limit of 4 hours.
- Recording to a rewritable CD is not recommended because it will not be able to write data quickly enough.
To record the live monitoring:
1. From the Utilities menu, select Record System Monitoring.
2. Specify the desired duration for the recording. Also specify where the recording is to be saved.
Fig. 3-73 Recording duration and filename
3. Click OK.
4. Using the recording controls, the recording duration can be extended in increments of 15s, 30s, 45s, or
1min-5min. Recording can also be stopped at anytime.
Fig. 3-74 Recording controls