78
Chapter3
OS32C
User’s Manual
Basic Operation of Configuration Software
Read Fault Log
There are separate fault logs for the sensor block and for the IO block. Each fault log contains the most recent
100 faults that have occurred. Fault entries are shown with the most recent faults first, so fault entry #1 is the
oldest fault.
To retrieve a fault log:
1. From the Utilities menu, select Read Fault Log.
2. Select sensor block or IO Block.
3. Print or save the error log to a text file.The example below is shown in printed form. When saved to a
text file, the data can later be exported to a spreadsheet.
Fig. 3-76 Fault Log
Page 1 of 10
Omron Scientific Technologies, Inc.
OS32C Configuration Tool - Version 1.7.10
Wednesday, July 31, 2013 - 09:15:31 AM
System Information
Sensor block serial#: AS00457S
I/O block serial#: AS00457B
Firmware version: 3.12
Model: OS32C_STANDARD
Minimum CFG Tool version: 1.5.0
FPGA version: 1.0
Compatible FPGA version: 1.0
Chronometer (h:mm): 1220:04
Product series: OS32C
Sensor name: Scanner at the corner
Angular resolution: 0.4°
Minimum object resolution (cm): 7.0
Ethernet Configuration
IP address: 192.168.40.100
Subnet mask: 255.255.255.0
Default gateway: 192.168.40.5
DHCP: Enable
MAC address: 00-0C-51-02-00-EE
Fault Log - Sensor block
Fault entry 41:
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for
more than 10 minutes).
Countermeasure 1: Check zone set select input connection and wiring and zone selection and zone delay configuration.
Countermeasure 2: Call Tech Support.
Category: 0x01 CRITICAL_MFG Chronometer (h:mm): 849:19
System state: STOP Temperature (°C): 30
Firmware version: 2.12 FPGA version: 1.0
Sensor block serial#: AS00457S I/O block serial#: AS00457B
Reference code: 0100-01554
Fault entry 40:
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for
more than 10 minutes).
Countermeasure 1: Check zone set select input connection and wiring and zone selection and zone delay configuration.
Countermeasure 2: Call Tech Support.
Category: 0x01 CRITICAL_MFG Chronometer (h:mm): 849:09
System state: STOP Temperature (°C): 30
Firmware version: 2.12 FPGA version: 1.0
Sensor block serial#: AS00457S I/O block serial#: AS00457B
Reference code: 0100-01554
Fault entry 39:
0x72 ZONE_SELECT_NUM_ACTIVE_FAULT
Description: Incorrect number of active zone set select inputs (hard fault code after diagnostic code 70 above persists for