91
OS32C
User’s Manual
Chapter4
Installation
E
Configuration Example: Installation on a Machine (2)
An example of installing a cover on the machine with undercut to mount the OS32C is shown below.
The OS32C needs to be installed so that the operator cannot stand between the safety zone and
danger zone.
Set a cover or undercut on the machine as shown in Fig. 4-9 so that the operator cannot stand on the
dead zone.
Fig. 4-9 Installation on a machine with cover
Put a cover on the OS32C as shown in Fig. 4-9 to cover the dead zone and prevent entry to the
"Undercut U and SFdistance"
The calculation example of safety distance S and SFdistance are the same as Configuration Example:
Installation on a Machine (1).
Configuration Example: Entry Access Protection
An application example for perpendicular approach to the scanning plane is shown below (entry
access protection for a vertical plane protection zone)
•Intrusion body detection protection
S
Z
Cover
SFdistance
H = 300 mm
Recessed mounting on the machine
eliminates the dead zone as shown
in the left figure.
Top View
Width of
danger zone
Safety zone
distance M
The OS32C measurement error Z1 (100mm)
Safety zone that needs setup by the configuration software
Machine table
Machine table
Side View
Danger
zone
Undercut U
Machine table
Additional error Z2 by reflective background