133
OS32C
User’s Manual
Chapter7
Appendix
E
Using Other Safety Device in Combination
If the OS32C is used for presence detection only, instead of intrusion detection, it is not necessary to
take the additional error Z
2 into account. Figures 7-2 and 7-4 show examples using OS32C for
presence detection only.
Configure the safety zone with a distance of 100mm or more, taking only OS32C's measurement error Z1 = 100mm
into account.
Fig. 7-3 Installing Safety Light Curtain on Entrance
Fig. 7-4 Installing Door on Entrance
Required distance from the wall = 100mm
The OS32C's maximum
measurement error Z
1
= 100mm
Safety light curtain
(e.g. F3SJ, MS4800)
Reflective background
or object
Danger zone
Actual configured zone
Required distance from the wall = 100mm
The OS32C's maximum
measurement error Z
1
= 100mm
Reflective background
or object
Reflective background or object
Danger zone
Safety door switch
Door
Actual configured zone