Protection of Cable at Installation:
Care should be taken when installing the OS32C cable. The cable must be properly routed and secured to
ensure that damage does not occur.
Signal Connector Isolation:
The connectors used during installation must
provide sufficient signal separation in order to prevent a short
circuit condition of the input power and system signals.
Functional Earth:
The OS32C system requires a functional earth connection.
Do not connect Functional Earth to a positive ground system. If it is connected to positive ground, the guarded
machine to be controlled may NOT stop, resulting in severe operator injury.