Synchronizing/Transferring a Whole Project
You can synchronize and transfer the EtherNet/IP connection settings along with the program data.
You can also transfer all the EtherNet/IP connection settings along with the program data.
Synchronizing and transferring the data
1
Establish an online connection between the computer and the Controller and then select
Synchronization from the Controller Menu. (Or, click the Button on the Toolbar.)
The Synchronization Window is displayed, and comparison of the user program and parameter
settings between the Sysmac Studio and the Controller is started.
2
The following Uploading and Downloading Data Window is displayed after the automatic com-
parison.
3
Clear the Do not transfer the EtherNet/IP connection settings (i.e., tag data link settings) Check
Box and then click the Transfer To Controller Button.
Then the EtherNet/IP connection settings are transferred along with the not-synchronized data.
If no EtherNet/IP connection settings are set in the Sysmac Studio, no data will be sent.

Table of Contents

Other manuals for Omron Sysmac NJ-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Sysmac NJ-series and is the answer not in the manual?

Omron Sysmac NJ-series Specifications

General IconGeneral
BrandOmron
ModelSysmac NJ-series
CategoryComputer Hardware
LanguageEnglish

Related product manuals