3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-14
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
_EIP_TDLinkErr Tag Data Link Com-
munications Error
NX-series CPU Units: Indicates that a tim-
eout occurred in a tag data link connection
for CIP communications 1.
TRUE: A timeout occurred.
FALSE: Other than the above.
NJ-series CPU Units: Indicates that a tim-
eout occurred in a tag data link connec-
tion.
TRUE: A timeout occurred.
FALSE: Other than the above.
BOOL TRUE or
FALSE
page 3-46
_EIP1_TDLinkErr CIP Communica-
tions1 Tag Data Link
Communications
Error
Indicates that a timeout occurred in a tag
data link connection for CIP communica-
tions 1.
TRUE: A timeout occurred.
FALSE: Other than the above.
Note You can use this system-defined vari-
able only for NX-series CPU Units.
BOOL TRUE or
FALSE
page 3-46
_EIP2_TDLinkErr CIP Communica-
tions2 Tag Data Link
Communications
Error
Indicates that a timeout occurred in a tag
data link connection for CIP communica-
tions 2.
TRUE: A timeout occurred.
FALSE: Other than the above.
Note You can use this system-defined vari-
able only for the NX701 CPU Units.
BOOL TRUE or
FALSE
page 3-46
Variable name Meaning Function Data type
Range of
values
Reference