5-22
5
C3-02
Slip com-
pensation
delay time
Sets the Slip Compensation
delay time.
Usually changing this setting
is not necessary.
Adjust this parameter under
the following circumstances.
• Reduce the setting when
Slip Compensation respon-
siveness is low.
• When speed is not stable,
increase the setting.
0 to
10000
200 ms
*1
No A No A No 210H
4-14
6-36
Slip Comp
Time
C3-03
Slip com-
pensation
limit
Sets the slip compensation
limit as a percentage of motor
rated slip.
0 to
250
200% No A No A No 211H 6-36
Slip Comp
Limit
C3-04
Slip com-
pensation
selection
during
regeneration
0: Disabled.
1: Enabled.
When the slip compensation
during regeneration function
has been activated and regen-
eration capacity increases
momentarily, it might be nec-
essary to use a braking option
(braking resistor, braking
resistor unit or braking unit.)
0 or 1 0 No A No A No 212H 6-36
Slip Comp
Regen
C3-05
Output volt-
age limit
operation
selection
0: Disabled.
1: Enabled. (The motor flux
will be lowered
automatically when the
output voltage become
saturated.)
0 or 1 0 No No No A A 213H 6-36
V/f Slip
Comp Sel
* 1. The factory setting will change when the control method is changed (The Open Loop Vecctor control factory settings are given.)
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
V/f
with
PG
Open
Loop
Vector
Closed
Loop
Vector
Display