5-37
5
F1-06
PG division
rate (PG
pulse moni-
tor)
Sets the division ratio for the
PG speed control card pulse
output.
Division ratio = (1+ n) /m
(n=0 or 1 m=1 to 32)
The first digit of the value of
F1-06 stands for n, the second
and the third stands for m.
This parameter is effective
only when a PG-B2 is used.
The possible division ratio set-
tings are: 1/32 ≤ F1-06
≤ 1.
1 to 132 1 No No A A A 385H 6-146
PG Output
Ratio
F1-07
Integral
value during
accel/decel
enable/dis-
able
Enables or disables integral
control during acceleration/
deceleration.
0: Disabled (The integral
function isn't used while
acceleration or
deceleration; it is used at
constant speeds only.)
1: Enabled (The integral
function is always used.)
0 or 1 0 No No A No No 386H 6-146
PG Ramp
PI/I Sel
F1-08
Overspeed
detection
level
Sets the overspeed detection
method.
Motor speeds that continue to
exceed the value set in F1-08
(set as a percentage of the
maximum output frequency)
for the time set in F1-09 are
detected as overspeed faults.
0 to 120 115% No No A No A 387H 6-146
PG Overspd
Level
F1-09
Overspeed
detection
delay time
0.0 to
2.0
0.0 s No No A No A 388H 6-146
PG Overspd
Time
F1-10
Excessive
speed devia-
tion detec-
tion level
Sets the speed deviation detec-
tion method.
Any speed deviation above the
F1-10 set level (set as a per-
centage of the maximum out-
put frequency) that continues
for the time set in F1-11 is
detected as a speed deviation.
The speed deviation is the dif-
ference between actual motor
speed and the speed reference
command.
0 to 50 10% No No A No A 389H 6-146
PG Deviate
Level
F1-11
Excessive
speed devia-
tion detec-
tion delay
time
0.0 to
10.0
0.5 s No No A No A 38AH 6-146
PG Deviate
Time
F1-12
Number of
PG gear
teeth 1
Sets the number of teeth on
the gears if there are gears
between the PG and the motor.
A gear ratio of 1 will be used
if one of these parameters is
set to 0.
0 to
1000
0NoNoANoNo38BH6-146
PG # Gear
Teeth 1
F1-13
Number of
PG gear
teeth 2
0NoNoANoNo38CH6-146
PG # Gear
Teeth 1
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
V/f
with
PG
Open
Loop
Vector
Closed
Loop
Vector
Display
PG Input Pulses x 60
F1-01
F1-13
F1-12
x