The screenshot below shows the wipe screen for an SSD that supports Sanitize.
Note: Wiping drives results in sustained writing of the media, which can
create abnormally high thermal operating conditions inside the drive.
OpenText highly recommends using the TX1-S1 drive bay (which has active
cooling) or an external drive cooler or fan when wiping media on TX1 to help
prevent thermal damage to drives.
The following table provides Wipe option details:
Option Description
Overwrite -
Single Pass
TX1 will write a constant pattern to the destination or accessory drive in a
single pass. If a custom wipe pattern is set, it will be written to the drive.
Otherwise, zeros will be written.
Verification is optional.
Note that when an HPA/DCO/AMA configuration is present on a drive, a
toggle may be set when configuring the wipe job to remove such
configuration prior to starting the wipe, which will ensure the entire
accessible drive space is overwritten.
Chapter 3 Configuring TX1