EasyManuals Logo

Oracle SPARC T8-2 User Manual

Oracle SPARC T8-2
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Replace the Battery
c.
Check the NTP policy for the /SP/clock.
-> show /SP/clock usentpserver
Properties:
usentpserver = enabled
d.
If enabled, set the property to disabled.
-> set /SP/clock usentpserver=disabled
2.
Replace the battery.
Replacing the battery is a cold-service procedure. The server must be completely powered off
and power cables disconnected before performing this procedure.
a.
Prepare the server for service.
b.
Remove memory risers CM0/MR0, CM0/MR2 and CM0/MR3.
c.
Remove the old battery.
Gently push the battery toward the memory risers to release it from the retention clip.
112 SPARC T8-2 Server Service Manual • June 2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T8-2 and is the answer not in the manual?

Oracle SPARC T8-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T8-2
CategoryServer
LanguageEnglish

Related product manuals