Component Service Categories
proper airflow through the system. Depending on the component configuration, the server can
include the following types of fillers:
■
Drive filler
■
PCIe card filler (covering back panel, not filling the connector slot)
Caution - When you remove a component while the server is connected to power, insert a
new component or filler within 60 seconds to ensure proper system chassis cooling. After
you complete cold-servicing, ensure that all fillers are in place before connecting the server to
power.
Related Information
■
“Servicing Drives” on page 63
■
“Servicing Memory Risers and DIMMs” on page 89
■
“Servicing PCIe Cards” on page 119
■
“Returning the Server to Operation” on page 171
Component Service Categories
The server components and assemblies that can be replaced in the field fall into three
categories:
■
Hot-service, replaceable by customer
■
Cold-service, replaceable by customer
■
Cold-service, replaceable by authorized service personnel
Cold service procedures require that you shut the server down and unplug the power cables that
connect the power supplies to the power source.
Although hot service procedures can be performed while the server is running, you should
usually bring it to standby mode as the first step in the replacement procedure. Refer to “Power
Off the Server (Server Power Button - Graceful)” on page 53 for instructions.
The following table identifies the components in each category.
Component service
Category
Component Service information Notes
Hot-service, replaceable by
customer
Drive “Servicing Drives” on page 63 Drive must be offline.
48 SPARC T8-2 Server Service Manual • June 2019