Reactivate RAID Volumes
Note - For more information on configuring hardware RAID on the server, refer to Servers
Administration.
8.
Unselect the SCSI device.
ok unselect-dev
9.
Confirm that you reactivated the volume.
ok probe-scsi-all
/pci@400/pci@2/pci@0/pci@e/scsi@0
FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00
Target a
Unit 0 Removable Read Only device TEAC DV-W28SS-R 1.0C
SATA device PhyNum 3
Target b
GB Unit 0 Disk SEAGATE ST914603SSUN146G 0868 286739329 Blocks, 146
SASDeviceName 5000c50016f75e4f SASAddress 5000c50016f75e4d PhyNum 1
Target 389 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 33b2999bca4dc677 VolumeWWID 03b2999bca4dc677
/pci@400/pci@1/pci@0/pci@b/pci@0/usb@0,2/hub@2/hub@3/storage@2
Unit 0 Removable Read Only device AMI Virtual CDROM 1.00
10.
Set the auto-boot? OpenBoot PROM variable to true so the server boots the OS
when powered on.
ok setenv auto-boot? true
11.
Reboot the server.
See Server Administration.
Related Information
■
“Install the Motherboard” on page 151
■
“Verify the Motherboard” on page 158
Servicing the Motherboard 157