Install a Power Supply
1.
If necessary, release the cable management arm to access the power supplies.
See “Release the CMA” on page 57.
Do not allow the CMA to hang unsupported while it is unattached.
2.
Align the power supply with the empty power supply chassis bay.
3.
Slide the power supply into the bay until it is fully seated.
4.
Move the release latch up to secure the power supply in place.
5.
Reconnect the power cord to the power supply.
6.
Verify power supply functionality.
See “Verify a Power Supply” on page 88.