EasyManua.ls Logo

Panasonic KX-TDA100 - Page 378

Panasonic KX-TDA100
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.7 Configuration [1]
378 Feature Guide
Feature Guide References
None
Flash—Flash Signal Detection (OPX)
Enables the PBX to detect the hookswitch flash signal from an SLT connected to OPX.
Default
Enable
Value Range
Disable, Enable
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
Flash—Minimum BREAK Width (OPX)
Specifies the maximum length of the break signal in a flash signal from an SLT connected to OPX.
Default
200 ms
Value Range
8 × n (n=3–63) ms
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
Flash—Flash Width (OPX)
Specifies the maximum length required by the PBX to recognize a hookswitch flash signal sent from an SLT
connected to OPX.
Default
800 ms
Value Range
8 × n (n=3–191) ms
Programming Guide References
4.7.1 Slot [1-1]