Version 7.11
78 | EN50131 Compliancy
Digiplex EVO • Programming Guide
Table 88: Description of Section [3037]
Table 89: Test Report Transmission (options 3 and 4 for Section [3037])
Partition Timers
Worksheet 58: Partition Timers (Partitions 1 - 4)
Worksheet 59: Partition Timers (Partitions 5 - 8)
Section Option Description OFF ON
Section [3037]
System Options 4
1Call back Disabled
Enabled
2 Automatic event buffer transmission Disabled
Enabled
3
Autotest report transmission options
Refer to Table 89 on
page 78
Refer to Table 8 9 on
page 78
4
5 Keypad beep on successful arming/disarming report Disabled
Enabled
6Alternate dialing Disabled
Enabled
7 Dial tone delay (if no dial tone) Disabled
Enabled
8
Report zone restore
ON = Upon zone closure
OFF = Upon bell cut-off
Disabled Enabled
Option
Description
3 4
OFF OFF
Transmit the test report code every time the days programmed in section [3040] have
elapsed, at the time programmed in section [3041]; (default)
OFF ON
When armed: transmit test report code every time the time programmed in section
[3042] has elapsed
When disarmed: transmit test report code every time the time programmed in section
[3043] has elapsed
ON OFF
The control panel will transmit the test report code every hour, on the minute value
programmed in section [3041] (the last two digits); the first two digits of section [3041]
will be ignored; for example, if 10:25 was programmed in section [3041], the test report
code would be transmitted at the 25th minute of every hour; i.e., 11:25, 12:25, etc.
ON ON
The test report code will be transmitted when one or more of the conditions of the
second and third options, listed above, are met; i.e., option 3 = OFF and option 4 = ON,
or option 3 = ON and option 4 = OFF
Description
(Decimal Values from 000 to 255)
Partition 1 Partition 2 Partition 3 Partition 4
Section Data Section Data Section Data Section Data
Number of invalid codes before lockout
(default: 010)
[3105] __/__/__ [3205] __/__/__ [3305] __/__/__ [3405] __/__/__
Keypad lockout duration
(default: 02)
[3106] __/__/__ [3206] __/__/__ [3306] __/__/__ [3406] __/__/__
Auto-zone shutdown
(default: 010)
[3114] __/__/__ [3214] __/__/__ [3314] __/__/__ [3414] __/__/__
Description
(Decimal Values from 000 to 255)
Partition 5 Partition 6 Partition 7 Partition 8
Section Data Section Data Section Data Section Data
Number of invalid codes before lockout
(Data x 1 attempt; default: 010)
[3505] __/__/__ [3605] __/__/__ [3705] __/__/__ [3805] __/__/__
Keypad lockout duration
(default: 02)
[3506] __/__/__ [3606] __/__/__ [3706] __/__/__ [3806] __/__/__
Auto-zone shutdown
(default: 010)
[3514] __/__/__ [3614] __/__/__ [3714] __/__/__ [3814] __/__/__