Version 7.11
78 | EN50131 Compliancy
Digiplex EVO • Programming Guide
Table 88: Description of Section [3037]
Table 89: Test Report Transmission (options 3 and 4 for Section [3037])
Partition Timers
Worksheet 58: Partition Timers (Partitions 1 - 4)
Worksheet 59: Partition Timers (Partitions 5 - 8)
Section Option Description OFF ON
Section [3037]
System Options 4
1Call back Disabled
Enabled
2 Automatic event buffer transmission Disabled
Enabled
3
Autotest report transmission options
Refer to Table 89 on
page 78
Refer to Table 8 9 on
page 78
4
5 Keypad beep on successful arming/disarming report Disabled
Enabled
6Alternate dialing Disabled
Enabled
7 Dial tone delay (if no dial tone) Disabled
Enabled
8
Report zone restore
ON = Upon zone closure
OFF = Upon bell cut-off
Disabled Enabled
Option
Description
3 4
OFF OFF
Transmit the test report code every time the days programmed in section [3040] have
elapsed, at the time programmed in section [3041]; (default)
OFF ON
When armed: transmit test report code every time the time programmed in section
[3042] has elapsed
When disarmed: transmit test report code every time the time programmed in section
[3043] has elapsed
ON OFF
The control panel will transmit the test report code every hour, on the minute value
programmed in section [3041] (the last two digits); the first two digits of section [3041]
will be ignored; for example, if 10:25 was programmed in section [3041], the test report
code would be transmitted at the 25th minute of every hour; i.e., 11:25, 12:25, etc.
ON ON
The test report code will be transmitted when one or more of the conditions of the
second and third options, listed above, are met; i.e., option 3 = OFF and option 4 = ON,
or option 3 = ON and option 4 = OFF
Description
(Decimal Values from 000 to 255)
Partition 1 Partition 2 Partition 3 Partition 4
Section Data Section Data Section Data Section Data
Number of invalid codes before lockout
(default: 010)
[3105] __/__/__ [3205] __/__/__ [3305] __/__/__ [3405] __/__/__
Keypad lockout duration
(default: 02)
[3106] __/__/__ [3206] __/__/__ [3306] __/__/__ [3406] __/__/__
Auto-zone shutdown
(default: 010)
[3114] __/__/__ [3214] __/__/__ [3314] __/__/__ [3414] __/__/__
Description
(Decimal Values from 000 to 255)
Partition 5 Partition 6 Partition 7 Partition 8
Section Data Section Data Section Data Section Data
Number of invalid codes before lockout
(Data x 1 attempt; default: 010)
[3505] __/__/__ [3605] __/__/__ [3705] __/__/__ [3805] __/__/__
Keypad lockout duration
(default: 02)
[3506] __/__/__ [3606] __/__/__ [3706] __/__/__ [3806] __/__/__
Auto-zone shutdown
(default: 010)
[3514] __/__/__ [3614] __/__/__ [3714] __/__/__ [3814] __/__/__

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series