ELECTRICAL INSTALLATION
ACR7000 Controller Controller Installation Guide 39
Encoder Trigger Input Specification
Description General Purpose High Speed
Turn-on time*
20 µs
300 ns
Turn-off time*
20 µs
300 ns
Threshold voltage rising
16.1V
16.1V
Threshold voltage falling
11.6V
11.6V
*On/Off time indicates propagation delay only. When used as general input, state change is detected at the PERIOD.