Technical data
104 (109) 192-011006N8 2019-07 09.10.19 09:27
8.8 Insulation requirements PSD1
Protection class in accordance with EN 60664-1
human contact with
In accordance with EN 61800-5-1
Voltage category III in accordance with EN 60664-1
8.9 Environmental requirements PSD1
General ambient
conditions
According to EN 60 721-3-3
Climate (temperature/humidity/barometric pressure): Class 3K3
temperatures:
(Relative humidity)
site
<=1000m above sea level for 100% load ratings
<=2000m above sea level for 1% / 100m power reduction
please inquire for greater elevations
Type of protection IP20 according to EN 60 529
With packaging (transport/ storage): 10 m/s
2
; 9 – 200 Hz
Without packaging: 10 m/s
2
Degree of contamination 2 in accordance with EN 60664-1 and EN 61800-5-1
8.10 cUL certification
UL508C, 3rd Edition, power supply load revision November 9th, 2010.
C22.2 N°.274-13, 12th Edition, last revision March 2013.
UL61800-5-1 1st Edition, issued June, 8th, 2012
C22.2 No.274-13, 1st Edition, issued March, 2013
The cUL approval is documented by a “UL” logo on the device (type specification plate).
8.11 EtherCAT characteristics