EasyManua.ls Logo

Parker PSD1-SW1200 - Output Data Servo Modules PSD1-M 3*400 VAC; Output Data of the PSD1-M Power Output Stages

Parker PSD1-SW1200
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
98 (109) 192-011006N8 2019-07 09.10.19 09:27
8.2.5. Output data servo modules PSD1-M 3*400 VAC
Category
Specifications
1)
Controller type
Number of power output
stage
Rated Output Current [A
rms
]
Pulse current for 2 s [A
rms
]
PSD1-M_1300
1
5
10
PSD1-M_1400
1
8
16
PSD1-M_1600
1
15
30
2)
PSD1-M_1800
1
30
60
2)
PSD1-M_2220
2
2 + 2
4 + 4
PSD1-M_2330
2
5 + 5
10 + 10
PSD1-M_2440
2
8 + 8
16 + 16
PSD1-M_2630
2
15 + 5
3)
30
2)
+ 10
PSD1-M_3222
3
2 + 2 + 2
4 + 4 + 4
PSD1-M_3433
3
8 + 5 + 5
3)
16 + 10 + 10
1)
At default setting of the switching frequency (see page 51).
2)
Minimum rotating field frequency for peak current at 15 A & 30 A output stages:
f > 3 Hz; with a rotating field frequency of f <3 Hz the maximum peak current duration is 100 ms
3)
Maximum total output current per device: 16 A.
8.2.6. Output data of the PSD1-M power output stages
Category
Specifications
Power output stage
2 A
5 A
8 A
15 A
2)
30A
2)
Input voltage
300 ... 750 VDC
Output voltage
3x 0-400 V (0...450 Hz)
Power at continuous
operation
1)
1.2 kVA 3 kVA 4.8 kVA 9 kVA 18 kVA
Power dissipiation
1)
20 W
45 W
75 W
105 W
220 W
Output currents
3)
With 400 VAC at the power module
I
Nominal
[Arms]
4 kHz
2
5
8
15
30
I
peak
(2 s) [Arms]
4 kHz
4
10
16
30
60
Nominal
[Arms]
8kHz
2
5
8
10
20
I peak
(2 s) [Arms]
8kHz
4
10
16
20
40
Nominal [Arms] 16 kHz
1.33 3.33 5.33 5 11
I peak
(2 s) [Arms]
16 kHz
2.67
6.66
10.66
10
22
Output currents
3)
At 480 VAC at the power module
I
Nominal
[Arms]
4 kHz
2
5
8
12.5
25
I
peak
(2 s) [Arms]
4 kHz
4
10
16
25
50
I
Nominal
[Arms]
8kHz
1.8
4.5
7.2
8
15
Ipeak (2 s) [Arms] 8kHz 3.6 10 14.4 16 30
INominal [Arms] 16 kHz
1.07 2.67 4.27 4 8.5
I
peak
(2 s) [Arms]
16 kHz
2.13
5.33
8.53
8
17
1)
For continuous operation with a mains supply of 400 VAC at the mains module.
2)
Minimum rotating field frequency for peak current at 15 A & 30 A output stages:
f > 3 Hz; with a rotating field frequency of f <3 Hz the maximum peak current duration is 100 ms
3)
Output current bei verschiedenen switching frequency. The default settings of the currents und switching
frequencies are grayed out & in bold.

Table of Contents