Technical data
98 (109) 192-011006N8 2019-07 09.10.19 09:27
8.2.5. Output data servo modules PSD1-M 3*400 VAC
1)
Number of power output
stage
rms
rms
2)
2)
3)
2)
3)
1)
At default setting of the switching frequency (see page 51).
2)
Minimum rotating field frequency for peak current at 15 A & 30 A output stages:
f > 3 Hz; with a rotating field frequency of f <3 Hz the maximum peak current duration is 100 ms
3)
Maximum total output current per device: 16 A.
8.2.6. Output data of the PSD1-M power output stages
2)
2)
Power at continuous
operation
1)
1.2 kVA 3 kVA 4.8 kVA 9 kVA 18 kVA
1)
3)
With 400 VAC at the power module
Nominal
peak
Nominal
I peak
Nominal [Arms] 16 kHz
1.33 3.33 5.33 5 11
I peak
3)
At 480 VAC at the power module
Nominal
peak
Nominal
Ipeak (2 s) [Arms] 8kHz 3.6 10 14.4 16 30
INominal [Arms] 16 kHz
1.07 2.67 4.27 4 8.5
peak
1)
For continuous operation with a mains supply of 400 VAC at the mains module.
2)
Minimum rotating field frequency for peak current at 15 A & 30 A output stages:
f > 3 Hz; with a rotating field frequency of f <3 Hz the maximum peak current duration is 100 ms
3)
Output current bei verschiedenen switching frequency. The default settings of the currents und switching
frequencies are grayed out & in bold.