192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07 09.10.19 09:27 21 (109)
Connecting protective earth
Connect protective earth via a copper wire of minimum
10 mm
2
by means of the provided screws at the bottom
of the PSD1M (axis controller) and of the mains module
PSD1-M_P:
2.10.5. Conditions of utilization for the cUL certification of PSD1-S
In this chapter you can read about:
• UL certification .......................................................................................................................... 21
• Installations- & Environmental Characteristics PSD1-S............................................................. 21
• Tightening torque of the wiring terminals .................................................................................. 23
• Auxiliary connection – electrical ratings .................................................................................... 23
• Data of integrated dynamic brake unit ...................................................................................... 23
• In- / Output Ratings .................................................................................................................. 23
2.10.5.1 UL certification
The UL certification is only valid if the type plate of the device shows the "UL" -sign.
UL61800-5-1 1st Edition, issued June, 8th, 2012
C22.2 No.274-13, 1st Edition, issued March, 2013
2.10.5.2 Installations- & Environmental Characteristics
PSD1-S
Risk of Electric Shock, wait at least 3 minutes with PSD1-S and 10 minutes with
PSD1-M before removing cover
• Use in Pollution degree 2 Environment.
• Maximum Surrounding Air Temperature 40 °C.