192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07 09.10.19 09:27 23 (109)
rated minimum 240 V (phase to ground), suitable for “Overvoltage Category III”,
and shall provide protection for a rated Impulse withstand Voltage peak of 4 kV.
2.10.5.3 Tightening torque of the wiring terminals
2
DSL® feedback / motor brake
2
ferrule with plastic sleeve
2
ferrule with plastic sleeve
2.10.5.4 Auxiliary connection – electrical ratings
DC Bus Input / Output – X63
400 VDC / D.C. / 7 A
Auxiliary Input Supply – X17
Control Supply - Max 24 VDC ±10% / max 0.5 ADC
Signal I/O’s Ports (PELV circuit) – X51
Signal I/O’s / Communication Ports - max 24 VDC / max 100 mA
2.10.5.5 Data of integrated dynamic brake unit
Internal DBU Ratings
Servo-Drive
Model Nos.
Max Current -
Amps
Max Duty Cycle -
per cent
Resistor
PSD1SW1200
PSD1SW1300
7.84 A 0.1 A 1.27 % (@60s) 51 Ω (40 W)
External DBU Ratings
Servo-Drive
Model Nos.
Max Current -
Max Duty Cycle -
per cent
Min Resistance
PSD1SW1200 7.84 A 0.15 A 1.91 % (@60s) 51 Ω (60 W)
PSD1SW1300 7.84 A 0.45 A 5.73 % (@60s) 51 Ω (180 W)
2.10.5.6 In- / Output Ratings
Input Ratings
Maximum Input Current
A rms
PSD1SW1200
3AC230 VAC ±10 % 50/60 Hz
PSD1SW1300
4.2
PSD1SW1200
1AC230 VAC ±10 % 50/60 Hz
PSD1SW1300
Output ratings
Device
Output
Voltage
Range of
Frequency
/ Phase
Max. Continuous
Output Power
kW
A rms
A rms
PSD1SW1200
0-230 VAC
0-400 Hz
/
Three-Phase
2 6 0.64
PSD1SW1300 5 15 1.1
Note: * "Duty Cycle": 20% @10 s (ON=2.0 s - OFF=8.0 s)