Installation of the individual drive PSD1-S
30 (109) 192-011006N8 2019-07 09.10.19 09:27
4.3.2. View from below (PSD1-S)
View from above (see page 30)
Central ground
connection
Connect ground via ring cable lug with a 10 mm
2
copper cable to central ground
X51 (see page 36)
To motor
HIPERFACE DSL® Motor feedback
Motor holding brake
and 24VDC feeding for the brake
Motor ground
connection
Connecting screw for motor earth/ the shielding of
the motor cable (see image bellow)
X52 (see page 35)
Connection of motor
Front view (see page 29)
Shows pin 1 of the connector
Wiring
Explanation
1
DSL connection
2
Motor brake connection
3
Connect ground via ring cable lug
with a 10 mm
2
copper cable to
central ground
4
Mounting of the shield terminal
with a flat connection to the motor
cable shield
5
Motor connection

Table of Contents