Installation of the multi-axis system PSD1-M
48 (109) 192-011006N8 2019-07 09.10.19 09:27
Status of axis
Left LED a
(green) (ready)
Right LED b
(red) (error)
6
Axis in error state / error
present / axis energized (error
on flashes quickly (5 HZ)
7
Axis in error state / error
present / axis de-energized
off on
Axis faulty: Please contact us
11
restoring from SD card
alternate quick flashing
(LEDa green, LEDb green)
12
restoring from SD card
alternate quick flashing
(LEDa red, LEDb red)
15
Axis de-energized
HEDA3 slave not ready
off Double flash
16
Axis energized
HEDA3 Slave not ready
on Double flash
17
Axis de-energized
HEDA3 Master not ready
off Triple flash
18
Axis energized
HEDA3 Master not ready
on Triple flash
Error response 1: Ramping with slow ramp; then deactivate control loops.
Error response 2: Ramping with "Stop" ramp, then deactivate control loops.
For the meaning of individuals errors please go to Error list.
Caution - Risk of electric shock!
High voltage supply may be present even with missing voltage supply (both