192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07 09.10.19 09:27 85 (109)
7.2.2.1 Motor output chokes ECM-0005-01 for PSD1-S (up to
7 A/ 1 mH)
For motor cable length > 50m
1 mH
7 A
Not defined
0 - 40 °C
Max. Elevation of operating site
1000 m above sea level
2.5 kg
Up to 7 A nominal motor current (1 mH)
Scale drawing:
Stated in mm
7.2.2.2 Output motor chokes ECM-0004-01 for PSD1-M (up to
6.3 A/ 3.6 mH)
For motor cable length > 20m
3.6 mH
6.3 A
IP00
0 -40 °C
Max. Elevation of operating site
1000 m above sea level
3.2 kg
Scale drawing:
Stated in mm