A3.2 FIRST TIME INSTALLATION
Please take care to situate the unit on a flat and firm surface. Do
not cover the air intakes of the unit. Please ensure free airflow
around the pco.aquamatic to ensure maximum cooling
performance. All tubes and power cords need to run kink-free.
Before installation of the unit carefully read the Innovatek Protect
IP safety datasheet (see Innovatek Website).
outlet flow
inlet flow
Please follow steps 1 – 6.
• Connect tubes to cooling unit and camera. The two arrows on the
housing of the cooling unit only indicate flow direction. Either
connection of the camera can be used for in or out.
• Attach power connection.
• Open tank cover.
• Turn power switch to on position (I).
• Slowly fill in the cooling application mixture while the unit is
running, you have to constantly refill liquid.
• While the cooling liquid flows back to the reservoir make sure that
the whole air escapes from the system – this takes a few minutes
(move hoses if necessary).
The cooling liquid reservoir (tank) is filled when liquid level is
approximately 1-2 cm from the top of the tank. The integrated pump
only works when the pump chamber is completely filled. To ensure
this please move hoses or remove air by evacuating. Reservoir
capacity is approximately 500 ml.
After steps 1 – 6 are completed successfully the system is ready for
operation.
NOTE
The hose connectors are waterproof in not connected state.
Maybe they lose one drop of cooling liquid from time to time. You
don’t have to empty the hoses while storing the camera system.