Special handling of the P1..P6 keys: These welding parameters are always accessible and are
reset to active, manual welding parameter sets (INUSE = 1).
In the current example, P31..P48 as well as P2 and P5 are reset
Display: P31: FREE .. P48: FREE in addition 2: P2MAN P5: P5MAN
The structure P1..P50 is buffered when the function is called. With the ESC key this structure
is read back again and all changes are thus undone.
End the function and return to input.
Terminate the function and return to production.
Note:
This function is primarily intended to reset all data records P1..P50 in order to then, e.g. for
a new product, to redefine the welding parameter sets and then to save them as a new pro-
gram package on the SD card with the PAK manager.
Roll basic position (for programmed welding)
This can be used to determine whether the transport rollers open or remain closed after a
welding program. The corresponding symbol is displayed depending on the selected basic
position. This function has no effect on manual or dynamic welding.