Input
76
Parameters
Parameter Value default Function
Link Roller Puller 0..2 2 Only visible with installed motorized puller
0 - no coupling - manually connect the puller
1 - Puller follows the upper roll when fully opened
2 - Puller always follows the upper role
Pedal Pos -1 200..800 600 With this the starting point of pedal position-1
can be set.
AmplErrorWindow 5..100% 100% - OFF error limit for amplitude welding
If the target and actual amplitude is more than this
Amount differ, error 15010 is displayed.
PwrErrorWindow 5..400W 400W - OFF error barrier for power welding
When target and actual performance by more than this
Amount differ, error 15011 is displayed.
SD - Recording 0..15 0 Save welding logs on SD (see SXXX)
Bit 0 - errors are recorded in the ERROR: TXT
logged
Bit 1 - short welding log
only min, max values
Bit 2 - extended welding protocol
(Min, max and measurement values)
Bit 4 - in addition with all the fucking parameters
saved (PAK)
VQLIM +/- 2400 550 parameters only after consultation with PFAFF
change
Show more 0,1 0 1: show further parameters
DUAL Cut & Seal 0..3 1 Depending on the equipment of the machine 0
or 1,2,3
0 - no DUAL Cut & Seal equipment
1 - DUAL Cut & Seal: cutting wheel extends
after the rollers are closed.
Total force = welding force + cutting force
2 - DUAL Cut & Seal: cutting wheel extends
before close the roles.
Total force = welding force + cutting force
3 - DUAL Cut & Seal: cutting wheel extends
before the roles close.
Total force = welding force
DUAL Ecotime 0..100min 5 Waiting time in the event of inactivity until
roles open and
Cutting wheel moves to switch-off position
Enable puller 0..1 0.1 depending on the equipment
0: no motorized puller installed
(LinkRollerPuller parameter invisible)
1: motorized puller installed
(LinkRollerPuller parameter visible)