Input
77
Parameter Value default Function
FRmode 0..20 0.1 parameters only after consultation with PFAFF change
Weighing Cell 0..15000 XXXXX Is determined by the machine itself - only serves as a
Spring factor information - do not change !!!
SONOTRODE -500..500 0 Threshold value of the sonotrode protective function
GUARD Limit (see SYYY) can be changed with the special function
DEBUG be determined
OpenRollers 0..2 2 0: Opening the roll does not lead to cancellation
AbortProgram 1: Opening the roll with the pedal leads to the abort
2: Opening a role always leads to termination
Piececountermode 0..1 0 0: Piece counter increments when canceled
Roll open
1: Piece counter increments when canceled and
after the program has run
Out1Pulse time 10..1000 * 10ms 30 Hold time of the Out1 output signal for Out1 pulse
function
Out2Pulse time 10..1000 * 10ms 30 Hold time of the Out2 output signal with Out2-Pulse
function
Dynstop 0..1 0 0: Pedal from Pos2 back to Pos1 stops
dynamic welding
1: Pedal from Pos2 back under Pos1 stops
dynamic welding not (continue with
Minimum speed)
DCacceleration * 0.01 ms2 200 Acceleration of the main axes
DCdeceleration * 0.01 ms2 200 Deceleration of the main axes