3.3 Using the device
Once you have completed and saved the configuration of the device, the
device will next adopt the set parameters. Make sure the device is
connected according to your configuration. After a few seconds, the
device can be reached again via one of the configured interfaces.
3.3.1 Remote maintenance option
The remote maintenance option gives you the opportunity to access and
communicate with the network participants connected to the device via
the Internet and another CONNECT device or the CONNECT software.
As soon as the device has completely booted up, the device's LED S1
begins to flash (not on the CONNECT-CONTROL devices).
If you have selected CONNECT as the connection type, you must next
communicate with the Internet from the PC connected to the CONNECT
device. This can e.g. B. the call ofwww.google.debe in your web browser.
Your CONNECT device should now have recognized the Internet
parameters from the PC and is ready for use. With the GATEWAY and
LTE connection types, the device is ready for operation without any
further action.
If you have activated automatic connection establishment in the device,
the CONNECT will now attempt to establish a connection to the
configured partner device. If you have not activated the automatic
connection establishment or would like to establish a connection to
another device, you can do this via the “Device list” dialog on the
“Overview” page of the web server.
As soon as the CONNECT device has established a connection to
another device from your CONNECT cloud, the LED S1 stops flashing
and instead lights up permanently (not for the CONNECT CONTROL
devices). The configured peripheral devices and, if applicable, the PC
(with the CONNECT connection type) can now communicate with the
devices of the partner device as if they were in the same network.
Important:
If you have deactivated the “remote access” setting, the device’s LED S1
will not flash. If you have selected the CONNECT connection type,
Page 29 Handbook CONNECT / CONNECT-II / CONNECT-CONTROL V1.13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PI CONNECT and is the answer not in the manual?

PI CONNECT Specifications

General IconGeneral
ModelPI CONNECT
CategorySwitch
Port Speed10/100/1000 Mbps
ManagementUnmanaged
MountingDesktop
Operating Temperature0°C to 40°C
Humiditynon-condensing
Ports8
Power over Ethernet (PoE)8 x PoE+ (802.3at)