4.2 Button
4.2.1 CONNECT / CONNECT-II device
The CONNECT / CONNECT-II devices have two buttons on the right
side. These have the following function:
• FS:Button to trigger factory settings
• T:currently not in use
If you want to reset your device to factory settings, you must press and
hold the “FS” button for at least 3 seconds. It is best to use a paper clip
to press the button.
After holding the button for 3 seconds and then releasing it, your device
will be reset to factory settings. The device then restarts and should be
accessible again after approx. 30 seconds with the standard settings, as
described in the “Commissioning” chapter.
4.2.2 CONNECT-CONTROL device
The CONNECT-CONTROL device has a button on the back that can be
operated with the supplied needle or a paper clip. The use of the button
can be individually parameterized in the Teltonika web interface. By
default, the following actions are triggered depending on the duration of
the key press:
min. time max. time Meaning
0 5 Restart
6 11 Restore user settings
12 20 Restore factory settings
Important:
Restoring user or factory settings also removes the CONNECT software
from the device. In this case, you will then have to completely reinstall
the software.
Page 39 Handbook CONNECT / CONNECT-II / CONNECT-CONTROL V1.13