Command Function
RTR
Gives the data recorder table rate. For the parameter concerned, see p. 67.
RTR?
Reads the current setting of the data recorder table rate.
VEL
Sets the value of the Servo Loop Slew-Rate parameter, ID 0x07000200.
VEL?
Reads the current value of the Servo Loop Slew-Rate parameter, ID 0x07000200.
WOS
Adds an offset to the wave generator output. For the parameter concerned, see
p. 112.
WOS?
Reads the current valid offset value.
WTR
Gives the wave generator table rate. For the parameter concerned, see p. 112.
WTR?
Reads the current setting of the wave generator table rate.
The following special command only changes the corresponding parameter in the nonvolatile
memory.
Command Function
IFS
Defines the default settings for communication via the RS-232 interface (baud rate;
p. 61) and TCP/IP interface (IP address, IP mask, IP start; p. 56).
For detailed command descriptions see the GCS commands manual PZ281E.
INFORMATION
The parameters listed above can also be changed with the general commands (p. 186).