The total number of points available for data recording is given by the Data Recorder Max Points
parameter, ID 0x16000200. The controller allocates these points in equal shares to the available
tables (i.e. to the number of tables given in the TNR? answer). For the E-727, the total number of
points is 262144. If, for example, TNR? replies 8, each table is comprised of 32768 points.
The data recorder sampling period can be read with the RTR? command. The answer gives the
value of the Data Recorder Table Rate parameter (ID 0x16000000) whose default value is one
servo cycle. You can cover longer periods by increasing this value. Use the RTR command or change
the parameter value directly in volatile memory.
Data-Recorder Related Commands and Parameters
Configuration
Assigns data sources and record options to data
recorder tables in volatile memory (DRC Data
Source parameter, ID 0x16000700, and DRC
Record Option parameter, ID 0x16000701)
DRC? Get Data Recorder
Configuration
Reads current data recorder settings
Points
Reads the number of points comprised by the last
recording.
Note: Reading can take some time, depending on
the number of points.
Set Data Recorder Trigger
Source
Determines how recording is to be triggered.
Settings will be lost on controller power down or
reboot.
Get Data Recorder Trigger
Source
Reads current trigger option
Options
Lists available record options, gives information
about additional parameters and commands
concerned with data recording
Response Measurement
RTR Set Record Table Rate Changes the data recorder table rate in volatile
memory (Data Recorder Table Rate parameter, ID
0x16000000)
RTR? Get Record Table Rate Reads the current setting of the data recorder
table rate (Data Recorder Table Rate parameter,
ID 0x16000000)
STE Start Step and Response
Measurement
Triggers recording
TNR? Get Number of Record
Tables
Reads the number of available data recorder
tables (Data Recorder Chan Number parameter,
ID 0x16000300)