HUNTER-PRO Series Installation Guide 23
3.2.5 I/O-8N, I/O-16, I/O-R
Each card must have a unique ID, determined by its dip-switch:
2 cards cannot have the same ID
I/O-8N IDs must be successive. The I/O-16 IDs are 1, 3, 5, 7
or 2 ,4 ,6 etc.
3.2.5.1 Expanders’ Numbering
Under the HUNTER-PRO series system, every 8 zones must have a unique ID;
Therefore, I/O-16 takes two IDs. Here’s an example for numbering few expansion
cards:
Card #1 Card #2 Card #3 Card #4
I/O-8N I/O-16 I/O-8N I/O-16
ID=1 IDs=2 and 3 ID=4 IDs=5 and 6
It is recommended to connect all the accessories GND (-) to the system’s
PCB. That includes power suppliers.
3.2.5.2 Examples of expanders and zone numbering:
Single I/O-8N/R card:
If EXP-PRO UNIV is installed: is numbered 17-24
If EXP-PRO UNIV is not installed: is numbered 9-16.
Two I/O-8N/R cards (16 zones):
If EXP-PRO UNIV is installed: are numbered 17-32
If EXP-PRO UNIV is not installed: are numbered 9-24.
Two I/O-16 cards (32 zones)
If EXP-PRO UNIV is installed: are numbered 17-48
If EXP-PRO UNIV is not installed: are numbered 9-40.
Single I/O-WN card (32 wireless zones):
If EXP-PRO UNIV and 2 I/O-8N cards are installed (32 zones in total) the I/O-
WN zones will be numbered 33-64.