76 HUNTER-PRO Series Installation Guide
[ENTR] causes the system to standby, waiting to receive data. Immediately press
‘Local’ icon
in COMAX to start the process. Wait until “Connected” message is
displayed on the COMAX status bar. You can now start downloading information.
5.10.3 Fast Load
8 EN TR ENTRBACK
Full Programming
ENTER/NEXT/END
Fast Load
ENTER/NEXT/END
Full
Select Prog. 1-7
- OR - NEXT
Communication
Select Prog. 1-7
1
...
7
Set the options for the PRG-896 fast programmer: The HUNTER-PRO series has 2
downloading options: full 7 different programs or only the communication parameters.
PRG-896 is programmed with COMAX software using DPR-33 adaptor
5.11 Key #9: Installer Code
EN TR
9
Installer Code
ENTER/N EXT/END
Installer Code
****** (4-6)
Set/change the Installer code. A code is 4 - 6 digits long.
If the Installer code begins with zero it is locked and cannot
be reset, in case of power loss. This is a security measure. If
this happens, please contact PIMA support team
5.12 Asterisk Key
*
: Express Programming Menu
*
Hour
00:00
For details, refer to section 4.5.
5.13 Key #0: Tests
Test menu has 9 sub-menus for testing the system’s hardwired and wireless zones, the
outputs, and the communication.
5.13.1 Walk-Test
0
ENTR
ENT R
Tests
ENTER/NEXT/END
Walk-Test
ENTER/NEXT/END
Tested0of9
Test all the line and wireless zones in the system. During the test, the display shows
the number of tested detectors out of the overall number of the detectors.