84 HUNTER-PRO Series Installation Guide
CH. 7. TROUBLESHOOTING
This chapter describes failures displayed on the keypad, various problems that may be
encountered due to improper programming, and options for troubleshooting failures
that might occur due to incorrect installation and/or programming.
7.1 Restoring the master & installer Codes
In case both these codes are not available:
1. Disconnect mains
2. Disconnect the battery
3. Wait 10 seconds and reconnect the battery
4. Wait for “Clock Not Set” to be displayed
5. Enter 5555 (default master code)
6. Press [9] and enter the new Master code (4-6 digits) and press [ENTR]
7. Press [END] to the main screen.
8. Press 1234 (default technician code) to enter the technician menu.
9. Press [9] and enter a new technician code (4-6 digits). Press [ENTR]
10. Connect mains.
11. Set time & date.
After connecting power, the system enables access to the menus
using the default master code (5555) for 30 seconds only. If access
does not occur during this time, the process needs to be repeated
The process is also useful for Installer code (Default code 1234),
with the exception of a code that begins with zero. In this case the
code cannot be reset and you need to call PIMA support
7.2 Faults Displayed on the LCD Keypad
In case a fault occurs, the red fault LED on the keypad flashes. The description of the
fault appears on the first line of the LCD Keypad at the right side. The faults are:
Fault Description & Repair
Clock Not Set Appears on first operation and when reconnecting after
power/battery failure. Set time & date
Low Battery 1. Make sure the battery fuse is intact.
2. Check battery charge voltage.
3. Wait 24 hours for recharging and recheck.
4. If the message stays on, replace battery.
Low Voltage Low PCB DC charge. Mostly occurs after long mains power failure
that causes the battery to get drained. Programming is
unavailable when this fault occurs. To repair: connect to mains
and replace battery if required.