52 HUNTER-PRO Series Installation Guide
5.4.3 Zone Sensitivity
Press [ENTR]
Sensitiv.(X50mS)
8
Set the zones’ sensitivity in milliseconds.
Sensitivity is the time a zone is violated before it triggers the alarm. The number
entered is multiplied by 50. In the screen above, entering 8 means a sensitivity of 8
times 50, that is 400 ms.
5.4.4 Zone Name
2
ENTR
ENTR
NEXT
Zones
ENTER/NEXT/END
Zone Name
ENTER/NEXT/END
Zone Number: 1
X2
Set the zones’ name. A name can have up to 13 characters. The keypad keys are used
for entering characters, similar to entering text in a cellular phone. See section 1.4
For example, to enter the words “REAR DOOR”:
1. Press [7] 3 times=R
2. Press [3] twice=E
3. Press [2] once=A
4. Press [7] 3 times=R
5. Press [0] once=Space
6. Press [3] once=D
7. Press [6] 3 times=O
8. Press [6] 3 times=O
9. Press [7] 3 times=R
5.4.5 Setting Partitions
2
ENTR ENTRNEXT
x3
Zones
ENTER/NEXT/END
Partitioning
ENTER/NEXT/END
Set the partitions to which the zones are allocated.
Setting the partitions along with setting the keypads’
partitions determines the nature of the system (i.e. Split
System/ Partitioned System).
Marking “+” allocates a zone to a corresponding partition.
Part. For Zone1
+---_-----------
Drawing 6 - Allocating
zones to a partition
For more details on partitions, refer to CH. 2.