3.16 Mains
Before connecting the power cord to the system, verify that
the cord is disconnected from mains
Connect the transformer to the AC terminals on the PCB and then to mains.
With an Ohm meter, check for continuity between the grounding point on the control
panel, PCB and GND terminal, to the electrical outlet grounding point. The resistance
must be less than 1 Ohm.
1. A current limiting device, such as circuit breaker or
fuse, must be connected in serial with the power cord
2. Electrical Grounding must be connected!
3.17 Initializing the System
Make sure the connections to the system are as described in previous sections.
Connect AC mains power supply.
Connect the backup battery to the fast connection terminals, red wire to (+)
and black wire to (-).
Close the control panel case and verify that the screws do not touch the battery.
If you connect the battery before mains, an AC fault will be
displayed until you connect the AC. The fault will be logged
Keypad Ver. 1.15
Keypad ID:0
When connecting to mains, the keypad will sound a
long beep and display the keypad version & ID screen
Starting
Please wait...
Few seconds afterwards the “Please wait” screen is
displayed
1 JAN 09 00:00
Clock not set
Then, the fault LED flashes, and a message that the
clock is not set is displayed. If faults exist, they will be
displayed one by one.
To turn the buzzer off, press
for 3 seconds. In case a new
fault occur the buzz returns. Only after all faults are resolved, the
red LED ceases to flash and the default display appears