HUNTER-PRO Series Installation Guide 55
5.5.1.3 PSTN Test Time and Interval
Test Time:00:00
Interval:24 Hrs
Set the daily time and interval for sending test events to the MS. If the time is left
00:00, the system will send the tests only according to the interval.
For example, if the test time is set to 23:00 (11 PM) and the interval to 3 Hrs, then test
reports will be sent every 3 hours and
everyday at 23:00. If the time is 00:00 and the
interval is set to 168 (hours), then the reports will be sent every 168 hours (once a
week). Press [ENTR].
Counting starts only when pressing the [ENTR] key
5.5.1.4 Radio Test Interval
Radio Tst. Inter
Hrs:24 Min.s:0
Set the radio test interval. See the previous sub-section for how-to. Press [ENTR].
5.5.1.5 ID Account Addition
If the account number is made of 6 digits, the first 2 are set in this screen. The rest 4
are set according to the next sub-section.
5.5.2 Account Numbers
3
ENTR ENTR
Communication
ENTER/NEXT/END
Account No.
ENTER/NEXT/END
NE XT
Acouont.No 1
Ph:0000 Rd:0000
Acouont.No 16
Ph:0000 Rd:0000
RadioTe lephone
Set the PSTN and Radio account numbers. There can only be 16 accounts (one for
each partition), each with a PSTN subscriber no. and radio subscriber no.
If all the accounts are the same, set only one account (open/close
events will be sent without the account number)
If no subscriber no. is entered, no reports will be sent to the MS
In a system with no partitions, reports will send from account #1