EasyManua.ls Logo

Pima Hunter-Pro 832 - Troubleshooting System Faults

Pima Hunter-Pro 832
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUNTER-PRO Series Installation Guide 37
3.13 MIC-200: Microphone Unit
1. Connect MIC-200’s CON to the control panel’s CONT terminal.
2. Connect MIC-200’s OUT to the control panel’s AUD IN terminal.
3. Connect MIC-200’s (-) and (+) to the detectors’ power source.
Control
Panel
Tamper
switch
Trimmer
MIC200
+
-
Z O N E S
Z8
MIC-200
(-)12(+) CON OUT TAMP
AUDIO
CON T
IN
OUT
(-)12(+) CON OUT TAMP
Figure 37. Connecting MIC-200 to the control panel
3.14 VU-20N: Dual Message Voice Unit
3.14.1 Single message programming
A zone that is supposed to trigger the VU-20N should be linked to ‘Audio device’ output
type. Since any output in the Hunter-Pro series can be triggered by any output type,
the VU-20N can be connected to any of the outputs, providing that the ‘Audio device’
output type was linked to it.
1. Navigate to a desired output (#7) and link the
‘Audio control’ output type to it
2. Press ENTR twice to Polarity and mark ‘-’
under ‘P’
3. Navigate to ‘Zone responses’ (#2), pick the
Zone Type that will trigger the VU-20N
‘Message 1’ and mark ‘+’ under ‘M - Activate
Audio’. Make sure the output trim time of ‘Audio
device’ is the default 60 seconds (#4)
4. Navigate to ‘Communication options’ (#3) and
mark ‘+’ under ‘V- Voice unit’
V
(+)
AUDIO
IN
VU20N
GND
()
Any
output
Single message
Blue
Red
Black
Green
Yellow
Loose
Figure 38. Single message
1) The Audio Control output polarity should be set to ‘+’ (see
section 5.9.4)
2) MIC-200 is supplied without wires

Table of Contents