88 HUNTER-PRO Series Installation Guide
7.3.6 Auto-Arming & Auto-Arming by Partition
Make sure that:
1. Auto-arming start time is programmed (see HUNTER-PRO series User guide).
2. System time is correct.
3. The desired partition is programmed as so.
7.3.7 Violating a Zone does not Set-off the Alarm
Make sure that:
1. The zone is neither temporarily nor permanently bypassed.
2. The zone is programmed to the desired responses (sirens, relay, etc.)
3. The zone is programmed to only one partition.
4. The detectors are in order and installed correctly.
5. Zone sensitivity is correct.
6. Zone conditioning is correct.
7. Zone no. of pulses is correct.
8. Zone is not programmed as soak zone.