70 HUNTER-PRO Series Installation Guide
Par. Name Marking “+” means…
Z - Not in use
T Byps. Tmpr. in Arm Arming is enabled with faulty tamper
F Byps. Fail in ARM Arming is enabled with system fault
Press [ENTR] to save and proceed to the second parameters screen.
5.7.2 General Parameters Second Screen
CLDSF12ZERPFCJAO
+-----+---------
Par. Name Marking “+” means…
C Light KP continu The keypad keys illuminate (weak) continuously
L Light KP in Alrm All keypads illuminate during alarms
D Light KP in Dely All keypads illuminate during exit/entry delays
S Buzzer In Alarm The Keypad buzzes in during alarms
F Enable Fast Arm Press the following keys until the exit countdown starts:
[1] to fully arm the system
[4] to arm the system to ‘HOME 1’ mode
[7] to arm the system to ‘HOME 2’ mode
1 Cancel HOME1 Del HOME1 entry delay time is ‘0’
2 Cancel HOME2 Del HOME2 entry delay time is ‘0’
Z Disp. Alrm in ON Alarmed zones are displayed when the system is armed
E Not in use -
R Retrigger Opn.Zn Triggered zones will be re-triggered and send reports to
the MS until they are closed or the system is disarmed
P Disp. Armed Part Armed partitions are displayed
F Final door Closing a delayed zone will terminate exit delay timing
C Full remote cont Enable full remote control (Mode B, including outputs)
J Report W/L Jamm. Wireless jamming is alerted & reported
A Part. AutoArming Auto-arming by partition is enabled
O Not in use
5.8 Key #6: System Responses
6
ENTR
ENTR
System Response
E NT ER / NE XT /E ND
Mains Fault
E N TE R/ NE X T/ EN D
SS AL
-- --
Set the system’s responses to 5 faults/events: Mains fault, low battery, phone line
fault, false code entry, and zone failure/tampering.