78 HUNTER-PRO Series Installation Guide
5.13.4 Set Soak Zone
0 ENTR ENTRNE XT
Set Soak Zone
EN TER /NE XT/E ND
X3
Zon e Num ber: 1
Ent r-Co nf #- Rst
ENTR
So ak Zo ne
Zo ne 1 - 1
Set a zone to be soaked (tested). When a zone/detector is suspected in causing false
alarms, they can be tested. A test can last up to 7 days (to set the number of soak
days, refer to section 5.6.6).
All the events from a tested zone will neither trigger the alarm, nor be reported to the
MS. However, they will be logged.
When the soak test is over, the zone will automatically return to normal mode.
To manually change a zone status from soak to normal mode, press [#] in the zone
no. screen.
5.13.5 Outputs Test
0 ENTR ENT RNE XT
Out put s Te st
ENT ER/ NEX T/E ND
X4
ENTR
O utp ut s Tes t
E xte rn al Si ren
Exi t=E ND
This feature lets you test every output directly - locally and remotely. Pressing [ENTR]
trips the output for 10 seconds. Pressing [END] ends the test.
Testing the outputs has a great advantage - it allows the installer to define between
connection problems and programming faults: if a device does not work properly but is
triggered by the output test, then the problem lays with programming (or the device
itself) and not connection.
On the other hand, failing to trigger the external siren (for example) through the
output test, indicates a connection or other-than-programming problem.
These are the outputs test screens by their order:
Output Key Presses Details
External Siren [ENTR] Onboard Ext. output
Internal Siren [ENTR] [NEXT] Onboard Int. output
Relay [ENTR] [NEXT] X2 Onboard Relay output
Smoke Output [ENTR] [NEXT] X3 Onboard Smoke output
On/OFF Output [ENTR] [NEXT] X4 Onboard ON/OFF output
ALARM Output [ENTR] [NEXT] X5 Onboard ALRM output
Audio Contrl Out [ENTR] [BACK] X4 Onboard Audio Cont. output
OUT-1000
Outputs
[ENTR] [BACK] X3 Press [ENTR], pick an output and press
[ENTR] to trigger it