Parameter Reference
96
UseExternalConferenceBridge Enables using an external conference
bridge for conference calls (SIP only). In
addition, the following rule
{cbridge:SPx(bridge-userid)}
must also be added to the handset port's
OutboundCallRoute parameter, where
x=1,2,3,4, and bridge-userid the userid of
the conference bridge SUA. Note that the
keyword cbridge is hard-coded and must
not be changed.
No
CallWaitingEnable Enables call waiting service. Call Waiting
is the situation where a new incoming call
is routed to the handset port when there
is
already another call connected. If this
service is enabled, the device plays the
call-waiting tone to alert you, as well as
generates the CWCID signal if CWCID is
enabled. You can then swap between the
two calls by hook flashing. If the service is
disabled, the device rejects the incoming
call as busy.
Note: Users can set this parameter from
the handset with a Star Code.
Yes
ToneProfile Selects a Tone Profile for call progress
tone generation.Choose from A or B.
A
StarCodeProfile Selects a Star Code Profile for
interpreting Star Codes you enter.
Choose from:
• None
• A
• B
If set to None, no star code is recognized
by the device.
A
LastDialedNumber Last number dialed out on the handset.
LastCallerNumber Last caller’s number that rings the
handset.
RepeatDialInterval Interval in seconds between retry in a
repeat dial operation.
30
RepeatDialExpires Duration of time in seconds when a
repeat dial operation remains active.
1800
Handsetn Settings Parameter Guide (n = 1, 2, ..., 9, 10)
Parameter Description Default Setting