System Configuration Flags
Polycom®, Inc. 788
NUMERIC_CONF_PASS_MIN_LEN Defines the minimum length required for the Conference
password.
Value: 0-16
Default:
•0 - (Standard Security Mode) this rule is not enforced. However
this rules cannot be disabled when the Collaboration Server is
in Ultra Secure Mode.
•9 - (Ultra Secure Mode) Conference password must be at least
9 characters in length (default).
OCSP_RESPONDER_TIMEOUT Not Supported in RMX 1800.
Determines the number of seconds the RMX is to wait for an
OCSP response from the OCSP Responder before failing the
connection.
Network latency or slow WAN links can cause login problems
when logging in to the RMX’s Management Network.This System
Flag’s value determines the number of seconds the MCU is to wait
for an OCSP response from the OCSP Responder before failing
the connection.
Default: 3 (seconds)
Range: 1-20 (seconds)
PAL_NTSC_VIDEO_OUTPUT When set to AUTO (default), the video output sent by the
Collaboration Server is either PAL or NTSC format, depending on
the current speaker in the layout. This ensures full synchronization
between the frame rate of the speaker and the video encoder,
ensuring smoother video.
In environments where the majority of endpoints are configured to
either NTSC or PAL, the flag can be set accordingly to change the
video encoding of the Collaboration Server to be compatible with
the majority of endpoints in the call.
Possible Values: AUTO, PAL, NTSC
PARTY_GATHERING_DURATION_
SECONDS
The value of this System Flag sets the duration, in seconds, of the
display of the Gathering slide for participants that connect to the
conference after the conference start time.
Range: 0 - 3600
Default: 15
For more information see Video Preview (AVC Participants Only).
PASSWORD_EXPIRATION_DAYS Determines the duration of password validity.
Value: between 0 and 90 days.
0 - user passwords do not expire. In Ultra Secure Mode: default -
60 days, the minimum duration is 7 days.
For details, see Defining Password Aging.
PASSWORD_EXPIRATION_DAYS_
MACHINE
Enables the administrator to change the password expiration
period of Application-user’s independently of regular users.
Default: 365 (days).